Search results for "water system"
showing 10 items of 19 documents
Lake restoration influences nutritional quality of algae and consequently Daphnia biomass
2020
AbstractFood quality is one of the key factors influencing zooplankton population dynamics. Eutrophication drives phytoplankton communities toward the dominance of cyanobacteria, which means a decrease in the availability of sterols and long-chain polyunsaturated fatty acids (EPA and DHA). The effects of different restoration measures on the nutritional quality of the phytoplankton community and subsequent impacts on zooplankton biomass have rarely been considered. We analyzed the nutritional quality of phytoplankton in the eutrophic Lake Vesijärvi in southern Finland over a 37-year period, and studied the impacts of two restoration measures, biomanipulation and hypolimnetic aeration, on th…
Lakes in the era of global change: moving beyond single‐lake thinking in maintaining biodiversity and ecosystem services
2020
The Anthropocene presents formidable threats to freshwater ecosystems. Lakes are especially vulnerable and important at the same time. They cover only a small area worldwide but harbour high levels of biodiversity and contribute disproportionately to ecosystem services. Lakes differ with respect to their general type (e.g. land-locked, drainage, floodplain and large lakes) and position in the landscape (e.g. highland versus lowland lakes), which contribute to the dynamics of these systems. Lakes should be generally viewed as ‘meta-systems’, whereby biodiversity is strongly affected by species dispersal, and ecosystem dynamics are contributed by the flow of matter and substances among locati…
Auswirkungen eines neuen Wassersystems auf nosokomiale Kolonisierung oder Infektion mit Pseudomonas aeruginosa
2016
Aim: We aimed to study the impact of new water systems, which were less contaminated with P. aeruginosa, on the incidence of healthcare-associated P. aeruginosa cases (colonizations or infections) in care units that moved to a different building between 2005 and 2014. Methods: Generalized Estimated Equations were used to compare the incidence of P. aeruginosa healthcare-associated cases according to the building. Results: Twenty-nine units moved during the study period and 2,759 cases occurred in these units. No difference was observed when the new building was compared with older buildings overall. Conclusion: Our results did not support our hypothesis of a positive association between wat…
Hospital Wastewater as a Reservoir for Antibiotic Resistance Genes: A Meta-Analysis
2020
Background: The emergence and dissemination of antibiotic resistance genes (ARGs) in the environment poses a huge global health hazard. Hospital wastewater (HWW), in which a high density of antibiotic residues and antibiotic-resistant bacteria are present, may be a reservoir of ARGs dissemination into the environment. Our meta-analysis comprehensively analyzes the prevalence of ARGs in HWW, as well as the influencing factors in ARGs distribution. Methods: Online databases were used to search for literature using the subject terms: “Drug Resistance” AND “Genes” AND “Hospitals” AND “Wastewater.” Two reviewers independently applied predefined criteria to assess the literature and extract data …
Multicriteria performance analysis of an integrated urban wastewater system for energy management
2017
AbstractThe optimization and management of an integrated urban wastewater system is a complex problem involving many processes and variables. The possible control options are defined by several management strategies that may differently impact the economic, operational or environmental performance of the system. The present paper aims to contribute to the environmental and energy sustainability of urban wastewater systems by means of a multicriteria performance analysis. The paper begins with a complete analysis of the system performance in several fields of interest (energy, environment, quality of service, operation, economy and financial resources), and it highlights the management stren…
Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and t…
2012
A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWS…
Lessons from the 2018-2019 European droughts : a collective need for unifying drought risk management
2022
Funding Information: This open-access publication was funded by the University of Freiburg. Funding Information: Financial support. The project is supported by the Wassernetzwerk Baden-Württemberg (Water Research Network of the State Baden-Württemberg), which is funded by the Ministerium für Wissenschaft, Forschung und Kunst Baden-Württemberg (Ministry of Science, Research and the Arts of the State Baden-Württemberg) (grant no. AZ. 7532.21/2.1.6) and Maa-ja vesitekniikan tuki ry foundation. Doris E. Wendt acknowledges her support as part of the NERC-funded Groundwater Drought Initiative (NE/R004994/1). Lucy J. Barker was supported by the Natural Environment Research Council (NE/R016429/1) a…
Występowanie pałeczek Legionella sp. w instalacjach wodnych obiektów użyteczności publicznej w województwie opolskim w latach 2010-2011
2012
CEL PRACY. Ocena kolonizacji sieci wodnej szpitali i obiektów użyteczności publicznej bakteriami Legionella sp. w województwie opolskim, w latach 2010 – 2011. MATERIAŁ I METODY. Ocenę przeprowadzono na podstawie wykonanych w latach 2010 – 2011 badań ciepłej wody w kierunku Legionella oraz meldunków sprawozdawczych MZ-56 i MZ-57 dotyczących zachorowań na choroby zakaźne. WYNIKI. Przeprowadzone badania ciepłej wody wykazały, że znaczący odsetek budynków użyteczności publicznej w woj. opolskim posiada skolonizowaną instalację wodną bakteriami Legionella sp. W grupie zbadanych obiektów, największy procent obiektów z kolonizacją sieci wodnej bakteriami Legionella sp. stanowią szpitale (2010 - 63…
Four-Year Environmental Surveillance Program of Legionella spp. in One of Palermo’s Largest Hospitals
2022
Legionella is a ubiquitous bacterium that lives in freshwater environments and colonizes human-made water systems. Legionella pneumophila is the most virulent species, and risk factors for Legionnaires’ disease include increasing age, smoking, chronic diseases, and immunodeficiency. For this reason, it is very important to assess and monitor hospital water systems in order to prevent legionellosis. We have monitored a large hospital in Palermo for four years. To determine the presence of microorganisms, according to national guidelines, we used the culture method, which is considered the gold standard for Legionella detection. Sampling was divided into five macro-areas, and a total of 251 s…
The effect of Water on passive cooling systems in the Arab-Norman architecture of the Zisa Palace in Palermo
2019
This paper shows the theories argued by some historians with reference to the working of natural water passive cooling systems employed in the Zisa Complex. Albeit such theories are seminal attempts to understand passive water systems, they have no scientific evidence. This study instead concentrates on a more rigorous treatment that enabled to set up a robust framework for designing a historical water passive system such as the Salsabil, which in fact was conceived and developed in an empirical way. Several historical buildings of the Mediterranean and Middle Eastern architecture include relevant artefacts useful to control humidity and temperature through water passive systems . The archi…